When it pertains to guaranteeing security in commercial, industrial, and property areas, slip resistance testing is a crucial element. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and property owners reduce dangers and abide by security standards.
With cutting edge equipment such as the pendulum slip test device and moisture meter for concrete, we provide accurate and independent slip testing services across Australia. Our know-how covers ASTM F2170 compliance, R Rating assessments, P Score tiles, and more, guaranteeing your floors meet the greatest safety benchmarks.
Why Slip Resistance Testing is Vital
Slips and falls are amongst the leading reasons for office and public injuries. Proper slip testing helps identify dangerous surface areas before mishaps take place. Whether you require damp pendulum test evaluations or pendulum test for slip resistance, ATTAR delivers accurate results to improve safety.
Key Services Provided by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Score and P Score tiles assessments.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing innovative moisture meter for concrete.
- ASTM F2170 certified evaluations.
- Concrete slab moisture testing to prevent floor covering failures.
3. Luminance Contrast Testing
- Ensures exposure for visually impaired individuals.
- Complies with Australian accessibility standards.
4. On-Site & Laboratory Testing
- Slip test machine for precise on-site examinations.
- Wet pendulum test for damp surface area slip resistance.
Understanding Slip Resistance Ratings: R Rating vs. P Rating
When performing slip resistance testing, 2 essential categories are used:.
- R Rating (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, frequently utilized in Europe.
- P Rating (Pendulum Test - AS 4586)
Assesses dynamic friction using a pendulum test slip resistance machine, widely adopted in Australia.
ATTAR supplies independent slip testing to figure out whether your floor covering satisfies the required pendulum score tiles standards.
The Importance of Concrete Moisture Testing
Excess moisture in concrete slabs can cause flooring failures, mold development, and adhesive destruction. Our concrete moisture testing services include:.
> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimal conditions for floor setups.
By finding moisture problems early, we help avoid expensive repairs and make sure lasting flooring efficiency.
Luminance Contrast for Ease Of Access Compliance
Proper luminance contrast is crucial for aesthetically impaired people to navigate spaces securely. ATTAR evaluates:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.
Our evaluations guarantee compliance with Australian Impairment Standards (AS 1428.1).
Why Select ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where appropriate).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Quick & Trustworthy Reporting.
For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Common Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping centres, dining establishments, and workplaces require safe flooring to prevent consumer and worker injuries. Our pendulum slip test guarantees compliance with safety regulations.
2. Industrial & Storage Facility Facilities
High-traffic commercial environments require long lasting, slip-resistant floor covering. ATTAR's slip testing services help maintain workplace security.
3. Healthcare & Aged Care Facilities
Medical facilities and nursing homes need to reduce slip more info risks. Our luminance contrast and slip resistance testing guarantee safe movement for patients and personnel.
4. Public Infrastructure
Paths, train stations, and government buildings need independent slip testing to meet ease of access and security standards.
How ATTAR Carries Out Slip Resistance Testing
Action 1: Surface Assessment
We examine flooring materials and conditions (dry, damp, or polluted).
Action 2: Pendulum Slip Test (AS 4663)
Utilizing a slip test machine, we measure the vibrant coefficient of friction (DCOF).
Action 3: Wet Pendulum Test
Mimics slippery conditions to evaluate real-world slip dangers.
Step 4: Reporting & Compliance Accreditation
In-depth reports with R Rating or P Score tiles categories.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance approach involves a swinging arm with a rubber slider that mimics a foot's motion. The test steps:.
- Slip Possible Value (SPV).
- Pendulum rating tiles classification (P0 to P5).
Greater rankings (P4/P5) suggest much better slip resistance.
Moisture Testing for Concrete Floors: Avoiding Failures
Moisture-related floor covering failures can be costly. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test information analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's relied on provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast assessments. With advanced technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and certified testing services.
Guarantee your property satisfies safety standards-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By selecting ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security options. Let us assist you develop more secure, certified, and moisture-resistant environments. Report this page